products

Anti Fracture H Root Canal Files 6pcs Single Size For Dental Treatment

Basic Information
Place of Origin: China
Brand Name: Feihuan
Certification: CE/ISO/FDA/FSC
Model Number: #15,#20,#25,#30,#35,#40
Minimum Order Quantity: negotiatable
Price: negotiatable
Packaging Details: 6 pcs/packing , single & assorted ,packed in box then carton 3000packings per cartoon: 48cm*40cm*35cm
Delivery Time: 10-15 working days after received the payment
Payment Terms: T/T, MoneyGram, Western Union
Supply Ability: 150,000 pcs / month
Detail Information
Product Name: Stainless Steel H Files Rotary Size: #15,#20,#25,#30,#35,#40
Taper: .02 Standard: CE/ISO/FDA/FSC
Application: Used With Endo Motor Length: L21/25/28/31mm
Material: Stainless Steel 304 Packing: 6pcs/packing
High Light:

root canal reamer

,

root canal treatment instruments


Product Description

Stainless Steel H Root Canal Files Anti Fracture For Dental Treatment

 

Stainless Steel H Files single size  Rotary use instruments  For dental treatment

 

 

Specifications:

Taper 2%
ISO Color #15 White
#20 Yellow
#25 Red
#30 Blue
#35 Green
#40 Black
Cross-section #15-40 Round

 

Description:

 

1. To prevent infection, sterilize the product with an autoclave and ensure sterilization is completed before use.
2. Choose the most suitable type for each case and follow the general principle of the method.
3. Before use, make sure that there is no deformation, scratches or cracks in the dental cavity. If the product's head is thin, long or large, it may break or distort. Because of this, we must avoid using unreasonable angles and excessive pressure.
5. Wear safety glasses to protect your eyes from injury. In addition, wear a dust mask to prevent inhalation of dust.
6. Wear rubber dam, avoid accidental swallow and fall.
7. Do not use this instrument for any purpose other than listing
8. This product is machine, you need to ensure that the speed of 250-350 rpm.
9. After use, dispose of as medical waste properly.
10. Dispose of if product is damaged or contaminated.
11. After use, rinse with a medical cleaner and wash away any foreign body such as bodily fluids and body.
12. When cleaning the product with an ultrasonic cleaner, place the product on the stand to avoid any deterioration of the working part.
13. Engien use files more effective and time saving 

Operation Sequence:

 

Work in quarters of rotations; then withdraw the instrument

For all preparation techniques with a filing motion

 

Warning:

 

1.Only skilled dentists are allowed to use.

2. Be sure to sterilize this product for each use.

3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use.

 

Precautions for use :

 

1. To prevent infection, sterilize the product by autoclave and make sure

sterilization is completed before using.

2. Choose the most appropriate type for each case and follow the general

method.

3. Before using, make sure the instruments outside of dental cavity that

there are no deformations, scratches and cracks.

4. If the head of product is thin, long or large, there are possibilities for

breaking or twisting. Because of this, be sure to avoid using

unreasonable angle and excessive pressure.

5. Wear safety glasses to protect your eyes from damage. Also, wear a

dust protective mask to prevent inhaling dust.

6. Wear rubber dam etc. to avoid accidental ingestion and falling.

7. Do not use this instrument for any purposes except for listed

applications above.

8. Only for use by dentists.

9. After using, follow an appropriate treatment as medical waste.

10. Dispose the product if damaged or contaminated.

11. After using, wash it with medical cleaning agent and brush, then

wash away foreign substances like adherent body fluids and body

tissues.

12. Set the product to a stand when cleaned by ultrasonic cleaner to avoid

working part deterioration.

13. Use this product with great care to avoid puncturing fingers because

of its possession of sharp-edged part.

 

 

Storages and duration of use:

 

1. Avoid storing at high temperature, humidity and direct sunlight.

Keep liquids away. Store it at room temperature.

2. Do not damage or make a pinhole to packaging materials.

3. Do not keep under germicidal lamp to avoid deterioration.

 

Maintenances and inspections:

 

1. Sterilize this product by autoclave under established method and

term for each use.

Method of sterilization:

Put this product in a sterilization pack or (or foil) and place it on a

sterilization tray, or files stand for autoclave sterilization with

reference to the following terms.

Terms for sterilization:

term(1) temperature: 121degrees Celsius time: 20 minutes or more

term(2) temperature: 126degrees Celsius time: 15 minutes or more

2. Do not use high pressure steam sterilizer which heats more than 200

degrees Celsius including drying process.

3. When reusing the instrument, wash away foreign substances

completely and sterilize.

4. Regarding use of medical cleaning agent, follow the instruction

manual by its manufacturer strictly.

5. Dispose the product if damaged or decreased in performance

 

Packages

 

1. Minimum packaging unit: 6 pcs. /package (#15,#20,#25,#30,#35,#40)

2. OEN also accepted , could be your owe design label 

 

 

Applications:

 

Dental Root Canal Treatment Hospital , Clinic , lab...

 

Competitive Advantage:

 

Strong and stable instruments for searching root canal ,cleaning and shaping the canal walls.

Enhanced safety – infection control made simple

TÜV-certified Quality Management

 

 

Anti Fracture H Root Canal Files 6pcs Single Size For Dental Treatment 0

Contact Details
Oscar

Phone Number : +8613316998403

WhatsApp : +8617552305712