products

Nickel Titanium Niti K Files , Engine Use K Files Endodontics For Root Canal Treatment

Basic Information
Place of Origin: China
Brand Name: Feihuan
Certification: CE/ISO/FDA/FSC
Model Number: #15 , #20 , #25 , #30 , #35 , #40
Minimum Order Quantity: negotiatable
Price: negotiatable
Packaging Details: 6 pcs/packing , single & assorted ,packed in box then carton 3000packings per cartoon: 48cm*40cm*35cm
Delivery Time: 10-15 working days after received the payment
Payment Terms: T/T, MoneyGram, Western Union
Supply Ability: 6,000 pcs / month
Detail Information
Product Name: Reamers For Engine Use NITI Size: #15 , #20 , #25 , #30 , #35 , #40
Taper: .02 Standard: CE/ISO/FDA/FSC
Application: Instruments For Smooth The Canal With Endo Motor Length: L21/25/28/31mm
Material: Nickel Titanium Color: White , Yellow , Red , Blue , Green , Black
High Light:

endo retreatment files

,

root canal reamer


Product Description

Nickel Titanium Single Size Root Canal Reamers Engine Use For Root Canal Treatment

 

Nickel Titanium Single size Root canal Reamers Engine use used for root canal treatment
 
 
Specifications:

Brand  Profa
Model Size #15 , #20 , #25 , #30 , #35 , #40 
Tper   .02
Lenth  L21/25/28/31mm
Usage   Recommend 8 canals 
Advantage  Strong flxibility and cuuting force with endo motor 

 
Description:
 
1. The needle is made from imported raw varnish material.
2. Using a high quality silicon stopper, measure the length of the root canal,
3. Each file with an explicit symbol of ISO size in the handle
4. Heritage of accuracy and quality transcending the era of Nittie
5. Instrument type and ISO size are specified on the handle.
6. ISO 08-80 made of triangle, suitable for extension, smoothing the canal
8. Provide accuracy and quality to enhance your expertise with stainless steel files.
9. Uniform structure special steel alloy excellent in fracture resistance and bending resistance
10. Radiopaque depth mark
11. Inert tip safely carries equipment along the canal
12. Pre-mounted silicone stopper
13. Available in aseptic packaging
 

 
Precautions for use:
 
1. To prevent infection, sterilize the product in an autoclave and sterilize it before use.
2. Select the optimal type for each case and follow the general guideline method.
3. Before use make sure there are no distortion, scratches and cracks in the cavity of the device's teeth.
4. If the head of the product is thin, long, or large, it may break or twist. For this reason, we need to avoid a unified perspective and excessive pressure.
5. Wear safety glasses to protect your eyes from scratches. Also, please wear a single dust mask to prevent inhalation of dust.
6. Wear rubber dams to avoid accidental swallowing or falling.
7. Do not use for applications other than this machine.
8. Only for dentists.
9. After use, please dispose appropriately as medical waste.
10. If the product is damaged or contaminated, discard it.
11. After use, please wash with medical cleanser and brush Please rinse off foreign matter adhering to body fluids and tissues.
12. When washing with an ultrasonic cleaner, please put it on the stand
The work is getting worse partially.
13. Be careful to use this product to avoid stinging your fingers It has sharp parts.
 
 
Storages and duration of use:
 
1. Avoid high temperature, humidity and direct sunlight stored.
2.Keep liquid away . Store it at room temperature.
3. Make sure  the packaging not damage , no pinhole.
3. Do not put under the germicidal lamp, in order to avoid deterioration.

 

 

Operation Sequence:

1. Preparation of the root canal walls.
2. General opening pulp.
3. Search and locate the root canal.

 
Maintenances and inspections:
 
1. Sterilize this product according to the correct method. 2.
Sterilization method:
Put this product in a sterile package or foil, place it in a sterilization tray for autoclave, and refer to the following terms.
Sterilization conditions:
(1) Temperature: 121 ° C. Celsius time: 20 minutes or more
(2) Temperature: 126 ° C. Time: 15 minutes
2. Do not use autoclave heated to 200 ° C or higher including drying process.
3. When reusing the equipment, please clear the completely disinfected file.
4. As for the use of medical cleansers, please follow the manufacturer's strict manual.
5. If the product is damaged or deteriorated, please discard the product
 
Warning:


1. Do not use this product except for the dental service and treatment.
2.Use it in accordance with the intended use.

3.Only skilled dentists are allowed to use.
4. Be sure to sterilize this product for each use.
 
Packages
 
1. Minimum packaging unit: 6 pcs. /package (#15,#20,#25,#30,#35,#40)
 
 
 
Applications:
Dental Root Canal Treatment Hospital , Clinic , lab...

 
Competitive Advantage:
 
Strong and stable instruments for searching root canal ,smooth  the canal walls.
Enhanced safety – infection control made simple
TÜV-certified Quality Management
Nickel Titanium Niti K Files , Engine Use K Files Endodontics For Root Canal Treatment 0

 
 
 

Contact Details
Oscar

Phone Number : +8613316998403

WhatsApp : +8617552305712